Modello: KNC1
marchio: Korlen / Youts
Frequency: 50/60hz
Electricity Type: Ac
Number Of Pole: 3
Phase: 3
Main Circuit Rating Voltage: 690v
Type: Ac Contactors
Rated Operation Current: 9a-150a
Rated Operation Voltage(V): 220v, 230v, 380v, 400v
Ambient Temperature: -5~+40
Action Principle: Electronic Type
IEC: Iec 60947-4
Load: High Power Relay
Coil Voltage: 24, 48, 110, 220, 230, 240, 380, 415, 440v
Main Circuit Rating Current: 100a
Pacchetto: cartone
produttività: 2000000pcs/month
Trasporti: Ocean,Air
Luogo di origine: Wenzhou Zhejaing Cina
Supportare: 1200000/MONTH
Certificati : ISO9001/ISO14001
Codice SA: 8536200000
Porta: Ningbo,Shanghai,Guangzhou
Tipo di pagamento: L/C,T/T,D/P,Paypal
Sfera di applicazione
Il contattore AC KNC1 in serie è applicabile sulla linea di AC 50/60 Hz, tensione valutata fino a 660 V e corrente nominale fino a 95A per interruttore remoto, rottura e avvio frequente, controllando il motore CA. Inoltre, il contattore può fungere da contattore di delay di tempo, reversibile
Contattore, Starter Stardelta con l'aggiunta di accessori come l'aggiunta del set di contatti ausiliari modulari. Testa di Air TimeDelay, meccanismo di interblocco meccanico, ecc. Inoltre, potrebbe fungere da antipasto elettromagnetico
dalla spina diretta del relè termico.
Questo prodotto è conforme al requisito degli standard IEC60947-4-1 e GB14048.4.
Relè termico
Relè di aggancio
Cina AC Contactor
Contatore magnetico
Produttore di valvole in stile wafer
Contattore AC
Parametro tecnico
Type |
Rated insulation voltage(V) |
Conventional thermal current(A) |
Rated operation current(A) |
Control power(kw) |
No.of contacts |
||||
220V 380V 415V | 440V 660V | ||||||||
KNC1- 0910 0901 |
20 | 9 | 2.2 | 4 | 4 | 4 | 5.5 |
3P+NO 3P+NC |
|
KNC1- 1210 1201 |
20 | 12 | 3 | 5.5 | 5.5 | 5.5 | 7.5 |
3P tN SP+N8 |
|
KNC1- 1810 1801 |
32 | 18 | 4 | 7.5 | 9 | 9 | 9 |
3P+NO 3P+NC |
|
KNC1-2510 2501 |
660 | 40 | 25 | 5.5 | 11 | 11 | 1115 |
3P+NO 3P+NC |
|
3210 KNC1- 3201 |
50 | 32 | 7.5 | 15 | 15 | 15 | 18.5 |
3P+NO 3P+NC |
|
KNC1-4011 | 60 | 40 | 11 | 18.5 | 22 | 22 | 30 |
3P+NO +NC |
|
KNC1-5011 | 80 | 50 | 15 | 22 | 25 | 30 | 33 | ||
KNC1-6511 | 80 | 65 | 18.5 | 30 | 37 | 37 | 37 | ||
KNC1-8011 | 125 | 80 | 22 | 37 | 45 | 45 | 45 | ||
KNC1-9511 | 125 | 95 | 25 | 45 | 45 | 45 | 45 |
Parametri della bobina
Type KNC1-09 KNC1-12 KNC1-18 KNC1-25 KNC1-32 KNC1-40 KNC1-50 KNC1-65 KNC1-80 KNC1-95 | ||||||||||||
Pick-up voltage 50/60Hz(V) |
(0.85~ 1.100s |
(0.85 1.1)Us |
(0.85~ 1.1)Us |
(0.85~ 1.1)Us |
(0.85~ 1.1)Us |
(0.85~ 1.1)Us |
(0.85~ 1.1)Us |
(0.85 1.1)Us |
(0.85~(0.85 1.1)Us 1.1)Us |
|||
Release voltage 50/60Hz(v) |
(0.2- 0.75)Us |
0.2~ 0.75)Us |
0.2~ 0.75)Us |
(0.2~(02~ 0.75)Us 0.75)Us |
02~ (02~ 0.75Us 0.75)Us |
0.2 0.75)Us |
02 (0.2- 0.75)Us 0.75)Us |
|||||
5 |
Pick-up(VA) 0 |
70 | 70 | 110 | 110 | 110 | 200 | 200 | 200 | 200 | 200 | |
Hz 60 |
Holding(VA) | 8 | 8 | 11 | 11 | 11 | 20 | 20 | 20 | 20 | 20 | |
Pick-up(VA) | 80 | 80 | 115 | 115 | 115 | 200 | 200 | 200 | 200 | 200 | ||
Hz | Holding(VA) | 8 | 8 | 11 | 11 | 11 | 20 | 20 | 20 | 20 | 20 | |
Power consumption 1.8-27 1.8~27 3~4 (W) |
3~4 | 3~4 6~10 | 6~10 6~10 | 6~10 6-10 |
Elenco prodotti : Contattore AC